Call Now

ELISA kit for Rattus norvegicus (Rat) Leptin Receptor (LEPR)

CD295; LEPR; OBR; LR

Description: Leptin Receptor (LEPR)

Organism Species: Rattus norvegicus (Rat)

Sample Type: Serum, plasma, tissue homogenates and other biological fluids.

Test Method: Double-antibody Sandwich

Assay Length: 3h

Detection Range: 1.56-100ng/mL

Sensitivity: The minimum detectable dose of this kit is typically less than 0.67ng/mL.

 

Specifity: This assay has high sensitivity and excellent specificity for detection of Leptin Receptor (LEPR). No significant cross-reactivity or interference between Leptin Receptor (LEPR) and analogues was observed.

Typical Standard Curve:

 

 

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Storage: Store at 4°C for frequent use. Stored at -20°C in a manual defrost freezer for one year without detectable loss of activity. Avoid repeated freeze-thaw cycles.

Notes: For In vitro laboratory use only. Not for any clinical, therapeutic, or diagnostic use in humans or animals. Not for animal or human consumption.

Recovery

Matrices listed below were spiked with certain level of recombinant Leptin Receptor (LEPR) and the recovery rates were calculated by comparing the measured value to the expected amount of Leptin Receptor (LEPR) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)77-9483
EDTA plasma(n=5)80-9682
heparin plasma(n=5)80-9483

 

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leptin Receptor (LEPR) were tested 24 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leptin Receptor (LEPR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

 

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Leptin Receptor (LEPR) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)92%-101%95-103%98-105%99-106%
EDTA plasma(n=5)91-101%93-102%82-91%87-93%
heparin plasma(n=5)94-104%83-95%96-97%89-102%

 

Reagents and materials provided

ReagentsQuantityReagentsQuantity
Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1×120µLAssay Diluent A1×12mL
Detection Reagent B1×120µLAssay Diluent B1×12mL
TMB Substrate1×9mLStop Solution1×6mL
Wash Buffer (30 × concentrate)1×20mLInstruction manual1

 

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

 

Test principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Leptin Receptor (LEPR). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Leptin Receptor (LEPR). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Leptin Receptor (LEPR), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Leptin Receptor (LEPR) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related Products:

Catalog NO. Product Name Product Type Organism species
KEW627Hu Leptin Receptor (LEPR) ELISA kit Homo sapiens (Human)
KEW627Mu Leptin Receptor (LEPR) ELISA kit Mus musculus (Mouse)
KEW627Ra Leptin Receptor (LEPR) ELISA kit Rattus norvegicus (Rat)
LW627Mu71 Leptin Receptor (LEPR) Biotin Linked-Polyclonal Antibody Mus musculus (Mouse)
MW627Hu22 Leptin Receptor (LEPR) Monoclonal Antibody Homo sapiens (Human)
MW627Ra21 Leptin Receptor (LEPR) Monoclonal Antibody Rattus norvegicus (Rat)
PW627Hu01 Leptin Receptor (LEPR) Polyclonal Antibody Homo sapiens (Human)
PW627Mu01 Leptin Receptor (LEPR) Polyclonal Antibody Mus musculus (Mouse)
PW627Mu02 Leptin Receptor (LEPR) Polyclonal Antibody Mus musculus (Mouse)
PW627Po01 Leptin Receptor (LEPR) Polyclonal Antibody Sus scrofa; Porcine (Pig)
PW627Ra01 Leptin Receptor (LEPR) Polyclonal Antibody Rattus norvegicus (Rat)
W627Hu01 Leptin Receptor (LEPR) Recombinant Protein Homo sapiens (Human)
W627Mu01 Leptin Receptor (LEPR) Recombinant Protein Mus musculus (Mouse)
W627Mu02 Leptin Receptor (LEPR) Recombinant Protein Mus musculus (Mouse)
W627Po01 Leptin Receptor (LEPR) Recombinant Protein Sus scrofa; Porcine (Pig)
W627Ra01 Leptin Receptor (LEPR) Recombinant Protein Rattus norvegicus (Rat)